Explosion-proof hydrocarbon gas alarm
Contact Info
- Room 405, 4th Floor, Xijun Building, No.4 Shangxue Road, Xinxue Community, Bantian Subdistrict, Longgang District, Shenzhen City,
- 陈工
- 19926530652
- 2183550010@qq.com
Introduction
Gas detector is a flameproof safety device that can quickly, reliably, stably and continuously detect gas concentration in industrial production. When the detected gas concentration reaches the preset alarm value of the gas detector, the detector will send an alarm and drive external equipment to remind on-site staff to take necessary protective measures, which can prevent gas-induced combustion accidents.
Working principle of gas detector: The detector installed on site operates with power supply. When gas leaks, the sensor converts the detected leakage amount into a corresponding voltage signal. After the voltage signal is processed by the detector, the data is uploaded and displayed on the screen. When the concentration reaches the set action value, the detector sends an alarm and drives external equipment.
Gas detector is a fixed instrument that can continuously detect oxygen concentration or toxic, harmful, flammable and explosive gas concentration in the working environment.
The gas detector adopts the diffusion method to convert the gas concentration signal at the monitoring point into an electrical signal in real time. The signal is amplified, then undergoes AD sampling, temperature compensation and intelligent calculation by the CPU to process the measurement result. If the measured value exceeds the set alarm concentration value, an alarm signal will be sent.
The gas detector adopts a dual-chamber design, special imported sensors, and the sensors adopt a modular design, making calibration and verification more convenient. It has superior performance, high stability, can output multiple sets of signals, and is easy to install and maintain, meeting the high reliability requirements of industrial site equipment.
Features
Ingenious structural design, extremely easy to install;
Upper and lower limit alarm points can be set arbitrarily within the full range;
Flameproof design, can be used in hazardous areas 1 and 2 under factory conditions;
Gas detector can be optionally equipped with a liquid crystal concentration display, which shows the concentration in real time on site;
Gas detector can be optionally equipped with a special flameproof acoustic-optic alarm to realize on-site acoustic-optic alarm;
Meets customers' requirements for any range from 1 to 99999 and all gas detection needs;
Two sets of normally open passive contact outputs, used for controlling contactors of fans or solenoid valves;
Exquisite power supply design, pure SMT component surface mount technology, making the product performance stable;
The sensor uses imported gas-sensitive elements, with high precision, long service life, small zero drift, fast response time, long-term continuous operation, small body, convenient operation and good anti-poison performance;
The alarm point adjustment, zero point adjustment and target point calibration of the transmitter can be performed without opening the cover through the controller;
Suitable for dozens of gas detections and can display gas names; Gas units: ppm, LEL%, VOL%, mg/m³;
International standard (4~20)mA signal can be directly connected to the factory DCS system, and RS485 digital signal is connected to the factory upper computer;
Accuracy | ±2%FS (high-precision type), ±5%FS (general type) |
Weight | 1.5Kg |
Warranty Period | 12 months |
Output Signal | 4-20mA/RS485/Passive Switch Quantity |
Interlocking Equipment | Fans, solenoid valves, fire systems, etc. (24VDC/1A) |
Flameproof Type | Intrinsically Safe Type |
Flameproof Mark | Ex d II C T6 Gb |
Working Voltage | DC12-24V±1% |
Dimension Specification | 140mm (length) * 164mm (width) * 75mm (height) |
Housing Material | Stainless steel / Aluminum alloy |
Sampling Method | Diffusion type or Pipeline type |
Temperature Grade | -40℃~+65℃ (regular type) / -40℃~+70℃ (extreme type) |
Humidity Grade | 15~95% RH (no condensation) |
Ambient Pressure | 86kPa ~106kPa |
Service Life | More than 3 years |
| Instruments & Meters/Other Instruments/Gas Alarms & Detectors | |